Adding Refrigerant to a Work Order via ServiceChannel Provider

When servicing a refrigerated work order, there are three options available when responding to the question "Did you add Refrigerant". If no refrigerants were added, then all the technician needs to do is to enter any non-refrigerated parts to the work order and close the work order. If refrigerants were added, the technician has two options, either to select yes, Refrigerants were added, in which case, the technician can then enter the refrigerants used, or the technician can select Enter Later. If the technician selects Enter Later,  the work order will be put into a status of Completed/Pending Refrigerant Use. Work orders that are in the status of Completed/Pending Refrigerant Use cannot be invoiced until the refrigerant data is entered to the work order. Additionally, if the technician selects Enter Later, the technician will not be able to enter the refrigeration information in ServiceChannel Provider. The refrigeration information will have to be entered in Provider Automation. However, if the technician only enters partial information, beyond Yes or Enter Later, then a follow-up work order will be created and dispatched to the provider, where the required information will have to be entered. When servicing a refrigerated work order, there are three options available when responding to the question "Did you add Refrigerant". If no refrigerants were added, then all the technician needs to do is to enter any other non-refrigerated parts to the work order and close the work order. If refrigerants were added, the technician has options, either to answer yes, Refrigerants were added, in which case, the technician can then enter the refrigerants used, or the technician can answer Enter Later. If the technician answers Enter Later,  the work order will be put into a status of Completed/Pending Refrigerant Use. Work orders that are in the status of Completed/Pending Refrigerant Use cannot be invoiced until the refrigerant data is entered to the work order. 

Refrigerant quantities used for when setting up a refrigerated asset or when making  subsequent additions due to a leak or expansion, must be recorded in accordance with local and national regulations. Therefore it is imperative that the technicians report their refrigerant use as soon as possible. Whether using Provider Automation or ServiceChannel Provider technicians can enter refrigerant use at the time of the work order or at a later time. If the technician is not entering the refrigerant usage at the time of the work order, then an acceptable time frame for entering all refrigerant usage should be discussed and agreed upon with the client.

Note: If the technician selects Enter Later, the refrigeration usage will have to be entered via Provider Automation, because the technician will no longer have access once they close the work order. , and check into it by tapping Check In.
  • Once you complete your work, tap Check Out, and then choose a work order status.
  • Pick resolution codes and a root cause.
  • Confirm using refrigerant on the work order by selecting Yes.

  • Panel
    bgColor#F9F9F9
    titleColor#0e3367
    titleBGColor#EAEAEA
    borderStylenone
    title⦿ How to Record Refrigerant Use on a Work Order via SC Provider
    1. Locate the desired work order.
    2. Tap Accept.
      Image Removed
    3. Tap Log Time,  to start the work order clock.
      Image Removed
    4. Tap Repair, to indicate that you are beginning to work on the work order.
    5. When the work order is complete, tap Stop.
      Image Removed
    6. Select one of the available statuses, then tap Done.
      Image Removed
    7. Add a  Work Summary, then tap Submit.
      Image Removed
    8. When prompted, "Did you use refrigerant" tap Yes.
      Image Removed
    Note
    Note

    You may see the Enter Later option in the Did you use refrigerant? pop-up that allows you to enter refrigerant use later. In this case, only users who have access to Provider Automation can specify this information at a later time.


  • Pick an asset on which you used refrigerant, and then tap Done.
  • On the Update Usage screen, tap Add Part.
  • On the Choose Source Location screen, select the location where the part originates from.

    Note

    Note: As an external provider, you will only see client inventory for the location the work order is assigned to.


  • Image RemovedSelect the Refrigerant used from the available list.
    Image RemovedFrom the list of parts, select the refrigerant part used.
  • Enter the Quantity used in pounds and ounces, then select the Reason why the refrigerant was added.
    Image Removed 

    Note

    If Unknown, Leak or Repair are chosen as the reason for the addition of refrigerant, and the amount added is sufficient, then the EPA Leak Record Calculation is done. If the leak record calculation breaches the established threshold, then additional information is required.


  • For each section where there is a red asterisk, select the appropriate value. 

    Note

    The sections must be completed in the order in which they are listed , as because subsequent section sections are dependent on the response entered into in the previous section.


  • Enter a Description of Work, then tap Done.
    Image Removed

  • The work order is now complete and the required Refrigeration information has been added.


    Panel
    bgColor#F9F9F9
    titleColor#0e3367
    titleBGColor#EAEAEA
    borderStylenone
    title⦿ How to Record Refrigerant Use on a Work Order via Provider Automation
    1. Locate the desired work order, then click Enter Refrigerant Usage.

      Note

      Note: The work order should be in the status of  Completed/Pending Refrigerant Use.


       Image Modified

    2. Select the asset from the list, then click the Save and Next button.

      Note

      Note:  If the asset is to be repaired, select the Repair radial button.  


      Image Modified

    3. On the Refrigerant Tracking  screen, first select whether the refrigerant was taken from Internal Inventory or Vendor Supplied.

      Note

      Note: You must first indicate where the inventory was taken from, as this effects other selections.


      1. From Internal Inventory:
        1. Select the Part Number from the dropdown list;
        2. Add the Amount of refrigerant used in pounds and fractions or pounds and ounces;
        3. Add a Part Description;
        4. Select the Date the refrigerant was used; 
        5. Select the Reason why the refrigerant was used; 

          Note

          If Unknown, Leak or Repair are chosen as the reason for the addition of refrigerant and the amount added is sufficient, then the EPA Leak Record Calculation is done. If the leak record calculation breaches the established threshold, then additional information is required.

          Image Modified

        6. Add another part, if necessary. If you do not need to add another part, click the Next button;

          Note

          Note: If the amount of refrigerant used was sufficient enough to exceed the leak threshold, a Leak Record will be created for the asset. 


        7. Complete the Leak Record, Then click the Next button; and
          Image Modified
        8. Add a description, the click the  Save button. 
          Image Modified
        9. The work order's status has changed from Completed/Pending Refrigerant Use to Completed/Pending Confirmation.
          Image Modified
      2. From External Inventory:
        1. Add the Part Number used;
        2. Add the Amount of refrigerant used in pounds and fractions or pounds and ounces;
        3. Add a Part Description;
        4. Select the Date the refrigerant was used; 
        5. Select the Reason why the refrigerant was used; 
          Image Modified

          Note

          If Unknown, Leak or Repair are chosen as the reason for the addition of refrigerant and the amount added is sufficient, then the EPA Leak Record Calculation is done. If the leak record calculation breaches the established threshold, then additional information is required.


        6. Add another part, if necessary. If you do not need to add another part, click the Next button;

          Note

          Note: If the amount of refrigerant used was sufficient enough to exceed the leak threshold, a Leak Record will be created for the asset. 


        7. Complete the Leak Record, Then click the Next button; and

          Image Modified
        8. Add a description, the click the  Save button. 
          Image Modified
        9. The work order's status has changed from Completed/Pending Refrigerant Use to Completed/Pending Confirmation.
          Image Modified


    Live Search
    spaceKeySCUCP
    additionalnone
    placeholderSearch our Knowledge Base
    typepage

    Panel
    titleColor#ffffff
    titleBGColor#5fa7d0
    borderStylegroove
    titleIn this Article

    Table of Contents
    maxLevel3
    minLevel2
    indent20px

    Panel
    titleColorwhite
    titleBGColor#75a346
    titleRelated Articles

    Filter by label (Content by label)
    showLabelsfalse
    max8
    showSpacefalse
    sorttitle
    cqllabel in ( "workorders" , "refrigeratedassetretorfit" , "refrigeration" , "refrigerationleakevent" ) and space = currentSpace ( )


    ...